{"product_id":"g8-hplc-automated-glycohemoglobin-analyzer-tos0021560-90sl-oo","title":"G8 HPLC Automated Glycohemoglobin Analyzer","description":"\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHbA1c \u003c\/strong\u003eResults in 1.6 Minutes with \u0026lt;2% CV Precision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNGSP \u003c\/strong\u003eand IFCC Certified Ion-Exchange HPLC Technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect \u003c\/strong\u003eStable HbA1c — No Sample Pre-Treatment Required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCap-Piercing\u003c\/strong\u003e Primary Tube Sampling with Integrated Barcode Reader\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree \u003c\/strong\u003eConfigurations: 90SL, 290SL, and Line Automation (LA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated \u003c\/strong\u003eStart-Up, Maintenance, and Shutdown .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e  .container {  display: flex;  align-items: center;  justify-content: left}\u003c\/style\u003e\n\u003cp\u003eThe\u003cstrong\u003e Tosoh Bioscience G8 HLC-723G8\u003c\/strong\u003e is a fully automated glycohemoglobin HPLC analyzer that delivers HbA1c results in 1.6 minutes using the gold standard ion-exchange method. Available in three configurations — 90-sample, 290-sample, and line automation — it scales from physician office labs to fully integrated high-throughput environments.\u003c\/p\u003e\n\u003ch4 style=\"text-align: center;\"\u003e✔ 1.6 Min\/Sample | ✔ NGSP \u0026amp; IFCC Certified | ✔ 3 Lab Configurations\u003c\/h4\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"margin-right: 15px; margin-bottom: 15px; float: left;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/6754\/5379\/files\/TOS0021560-90SL-Fast-Results_480x480.jpg?v=1780463364\"\u003e\u003c\/div\u003e\n\u003ch4\u003eFAST, ACCURATE RESULTS EVERYTIME\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eHbA1c IN 1.6 MINUTES: \u003c\/strong\u003eIon-exchange HPLC delivers stable HbA1c (SA1c) results with intra-assay CVs as low as 0.42% and inter-assay CVs as low as 0.36%, well under the 2% threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGOLD STANDARD METHODOLOGY:\u003c\/strong\u003e The same ion-exchange HPLC method used in the landmark DCCT study. NGSP and IFCC certified for reliable, compliant reporting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNO INTERFERENCE FROM LABILE A1c: \u003c\/strong\u003eResults are not clinically affected by labile HbA1c, most hemoglobin variants, or derivatives. No offline pre-treatment needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVARIANT DETECTION INCLUDED: \u003c\/strong\u003eA simple mode switch activates the β-thalassemia program for in-depth hemoglobin variant analysis without changing workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFIRST RESULT IN 3.5 MINUTES:\u003c\/strong\u003e Pre-reaction takes 1.9 minutes; analysis runs in 1.6 minutes, faster than any previous G-series model.\u003c\/p\u003e\n\u003cdiv class=\"container\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0728\/6754\/5379\/files\/TOS0021560-90SL-Configurations_480x480.jpg?v=1780464001\" style=\"margin-top: 15px; margin-right: 15px; margin-bottom: 15px; float: left;\"\u003e\u003c\/div\u003e\n\u003ch4\u003eCHOOSE THE CONFIGURATION THAT FITS YOUR LAB\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003e90SL — MID-VOLUME LABS:\u003c\/strong\u003e Loads 90 samples + 1 STAT position. Compact at 21\"W × 20\"D × 19\"H \/ 75 lbs . Fits physician office labs, clinics, and smaller hospital labs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e290SL — HIGH-VOLUME LABS: \u003c\/strong\u003eLoads 290 samples + 1 STAT position at 44\"W × 21\"D × 19\"H. Built for core labs and reference labs with high daily volumes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLA — LINE AUTOMATION\u003c\/strong\u003e: At 21\"W × 29\"D × 19\"H, the LA integrates into a full lab automation line via sample belt, no manual loading required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFLEXIBLE TUBE LOADING:\u003c\/strong\u003e All three models accept mixed tube sizes and types, loaded continuously in the same rack in any order.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUPGRADE AS YOU GROW:\u003c\/strong\u003e Scale from 90SL to 290SL or LA as volumes increase. Core performance stays consistent across all configurations.\u003c\/p\u003e\n\u003cdiv class=\"container\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003eWhether you're running a small clinic or a fully automated reference lab, the G8 delivers the speed, precision, and scalability to keep your HbA1c workflow running without interruption.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" height=\"14\" width=\"17\" src=\"https:\/\/tigermedical.com\/cdn\/shop\/files\/global_warning.png\"\u003e \u003cstrong\u003eWARNING\u003c\/strong\u003e: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to \u003ca title=\"\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e","brand":"NDC [Dropship]","offers":[{"title":"Default Title","offer_id":55429357830435,"sku":"TOS0021560-90SL-","price":41483.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/6754\/5379\/files\/TOS0021560-90SL_71241d6c-3d5c-421d-ae38-0e298a235206.jpg?v=1785936050","url":"https:\/\/tigermedical.com\/products\/g8-hplc-automated-glycohemoglobin-analyzer-tos0021560-90sl-oo","provider":"Tiger Medical","version":"1.0","type":"link"}