  • 50-Tube Continuous Autoloader with Walk-Away Operation
  • 5-Part Differential via Dynamic Gating w/ 40% Fewer Flags
  • Accurate Results from as Little as 17 µL Sample Volume
  • Up to 30,000 Patient Records with Bidirectional LIS
  • Autonomous Daily Startup and Cleaning
  • Compact Footprint, Up to 1/3 Less Counter Space .

✔ 50-Tube Autoloader | ✔ 17 µL Micro-Sample | ✔ Walk-Away Automation

The Beckman Coulter DxH 560 is a compact autoloading hematology analyzer that delivers accurate 5-part differential results with minimal manual intervention, even from difficult-draw patients like infants, geriatric, and oncology cases. It runs itself through daily startup and cleaning, so your staff can stay focused on results, not the instrument.

LOAD IT AND LEAVE IT

CONTINUOUS 50-TUBE LOADING: Load samples and keep analysis running without stopping, up to 2x the capacity of the closest competitor.

HANDS-FREE DAILY STARTUP: The DxH 560 runs its own pre-programmed maintenance and system checks every morning, no bleaching or manual setup required.

FAST TURNAROUND: Results in 60 seconds or less with an intuitive touchscreen, any function accessible in three touches or fewer.

ONLY TWO REAGENTS TO MANAGE: Store and replace just two reagents for a full CBC/Diff, each swappable in under two minutes with barcode-assisted lot tracking.


RESULTS YOU CAN TRUST

PROPRIETARY DYNAMIC GATING: Automatically adjusts cell-population thresholds in real time, reducing unnecessary slide review flags by 40% compared to static gating without sacrificing clinical sensitivity.

WORKS WITH TINY SAMPLES: An aspiration volume of just 17 µL means fewer redraws from infants, oncology patients, and other hard-to-draw cases.

PEDIATRIC REFERENCE RANGES: The DxH line is the first hematology analyzer portfolio with comprehensive age- and sex-specific pediatric ranges built in.

PHI-PROTECTED RESULTS: Customizable user logins, automated timeouts, and account lockout thresholds keep patient data secure.


DATA THAT WORKS AS HARD AS YOU DO

30,000-RECORD ONBOARD STORAGE: Holds up to a full year of patient results with delta check and file retrieval built in.

EXTENDED QC ONBOARD: Monitor bias, precision, and accuracy without internet access or extra fees, Levey-Jennings graphs and XB/XM methodologies included.

BIDIRECTIONAL LIS INTERFACE: Ethernet and RS-232 support reduces transcription errors and keeps records synced automatically.

COMPACT BY DESIGN: At 19.7 x 18.1 x 17.3 inches with an integrated screen and keyboard, the DxH 560 uses up to a third less counter space than comparable analyzers, with only one external reagent required.


With autonomous operation, a space-saving design, and results reliable enough for the most vulnerable patients, the Beckman Coulter DxH 560 Hematology Analyzer is built to keep low- to mid-volume labs running at full capacity every day.

Warning WARNING: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

  • 50-Tube Continuous Autoloader with Walk-Away Operation
  • 5-Part Differential via Dynamic Gating w/ 40% Fewer Flags
  • Accurate Results from as Little as 17 µL Sample Volume
  • Up to 30,000 Patient Records with Bidirectional LIS
  • Autonomous Daily Startup and Cleaning
  • Compact Footprint, Up to 1/3 Less Counter Space

What’s in the Box

  • Beckman Coulter DxH 560 AL Hematology Analyzer
  • User Manual
  • Warranty

RETURNS: ITEMS WITH A LEAD TIME LONGER THAN 48 HOURS CANNOT BE RETURNED / CANCELLED. These are specially ordered, and we cannot accept returns or cancellations on such products for any reason. We take the responsibility to make sure your product arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.

Items which ship out in 24-48 hours are covered by our standard 30 day return policy from date of shipment. Return shipping charges are the responsibility of the customer. The product must be in new condition and in its original packaging.

For complete details of our return policy and process, please refer to our general return policy page.

Dimensions
Depth
18.1 in.
Height
17.3 in.
Weight
48.5 lbs.
Width
19.7 in.
Base Properties
Throughput
55 closed-tube samples/hr; 60 open-tube samples/hr
Sample Volume
17 µL of venous or micro-collected whole blood
Data Storage
30,000 patient results including graphics, flags, codes, and messages
Quality Control
12 control files, max 150 runs each; LJ plots, XB, XM, eIQAP with QC auto rerun
Sample No
50-tube continuous feed capacity
Peripheral Output Options
Optional USB printer (laser or inkjet); 5x USB 2.0 ports
Processing system
Not specified
Dryer
N/A
Temperature (refrigerated chamber)
N/A
Cleaning agent
DxH 500 Series Cleaner (500 mL) — Part No. B36868
Waste disposal
Not specified
Slide collection drawer
Not specified
Parameters
CBC Results
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV
Differential Results (absolute and %)
LY%, LY#, MO%, MO#, NE%, NE#, EO%, EO#, BA%, BA#
Reticulocyte Results (absolute and %)
Not specified
Manufacturer’s reagents
DxH 500 Series Diluent (B36845), Lyse (B36846), Cleaner (B36868), Calibrator (B36880), Control tri-level sets (B36872)
Body Fluids (Spinal, Serous and Synovial)
Not specified
Power
Power Consumption
Less than 120W
Power requirements
100–240 VAC, 50–60 Hz, single phase with ground
Whole Blood Performance - Measuring Range
WBC
Not specified
RBC
Not specified
HGB
Not specified
MCV
Not specified
PLT
Not specified
Sample Transport Capabilities
Capacity
50-tube continuous feed autoloader
Stain
Stained slide dryer
N/A
Carrier, continuous load
N/A
Slides/hr
N/A
Cellular applications
N/A
Other attributes
N/A