Please ensure Javascript is enabled for purposes of website accessibility Skip to content

Your Cart (0)

View cart

Your cart is empty

Continue shopping

EasyOne Pro Portable DLCO, Lung Volume & Spirometry Analyzer

by NDD
MFR#: 3000-1
TIGER#: TM166019
Original price $31,923.82 - Original price $31,923.82
Original price List Price: $31,923.82
$32,170.66
$32,170.66 - $32,170.66
Current price $32,170.66
Add to cart for Lower Price
EasyOne Pro Portable DLCO, Lung Volume & Spirometry Analyzer
EasyOne Pro Portable DLCO, Lung Volume & Spirometry Analyzer - $32,170.66
$32,170.66
*Must Purchase 1 for EasyOne Pro Portable DLCO, Lung Volume & Spirometry Analyzer

The cart will thereforce automatically set Qty to 1 when you order this product

Ships Out Within: 14 - 21 Business Days
  • PARAMETERS: FVC, FVL,SVC, MVV, DLCO, Lung Volumes, Provocation and Pre/Post Testing
  • Calibration-Free TrueFlow Ultrasonic Flow Technology
  • TrueCheck Automated Quality Control for DLCO Accuracy
  • Compact and Lightweight at 17.65 lbs (8 kg)
  • HL7, XML, and GDT EMR Connectivity .

✔ Calibration-Free TrueFlow Tech | ✔ Compact 17.65 lb Design | ✔ No Body Box Needed

The ndd EasyOne Pro delivers accurate spirometry, DLCO, and single-breath lung volume testing at the point of care, no body box and lengthy calibrations required. Built on patented TrueFlow and TrueCheck technology, it eliminates calibration and common sources of error so your practice gets dependable results, test after test.


ACCURATE RESULTS, ZERO CALIBRATION

CALIBRATION-FREE FLOW MEASUREMENT: TrueFlow ultrasonic technology delivers accurate, repeatable flow results without daily calibration checks.

AUTOMATED QUALITY CONTROL: TrueCheck verifies gas-sensor accuracy through a patented 5-point check, so DLCO trials stay validated without external simulators or warm-up time.

ALL-IN-ONE TESTING: FVC, FVL, SVC, MVV, provocation, pre/post, and DLCO testing all run on one unit, no body box needed for lung volumes.


DESIGNED FOR THE PRACTICE, NOT THE LAB

INSTANT-ON, LOW-MAINTENANCE OPERATION: Switch on and start testing immediately, with annual maintenance taking about 10 minutes in-house, no warm-up cycle or service call needed.

COMPACT FOOTPRINT: At 17.65 lbs. (8 kg), the EasyOne Pro fits easily into any exam room or office setting.

SEAMLESS EMR INTEGRATION: Connects to virtually any EMR/EHR system via HL7, XML, or GDT.

STANDARDS-BASED ACCURACY: Meets ATS/ERS 2022, 2019, and 2005 spirometry standards, plus NIOSH, OSHA, and SSA Disability testing requirements.

HYGIENIC, SINGLE-PATIENT CONSUMABLES: Spirette and DLCO Barriette consumables reduce cross-contamination risk and minimize cleaning between patients.


AVAILABLE OPTIONS

  • EasyOne Pro w/ 2-Year Warranty (3000-1)
  • EasyOne Pro w/ Cart, Color Inkjet Printer, 100x Spirettes, 100x DLCO Barriettes, 3-Year Warranty (3000-1K)

With calibration-free accuracy and minimal upkeep, the ndd EasyOne Pro is built to deliver reliable pulmonary function testing for years to come.

Warning WARNING: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

  • PARAMETERS: FVC, FVL,SVC, MVV, DLCO, Lung Volumes, Provocation and Pre/Post Testing
  • Calibration-Free TrueFlow Ultrasonic Flow Technology
  • TrueCheck Automated Quality Control for DLCO Accuracy
  • Compact and Lightweight at 17.65 lbs (8 kg)
  • HL7, XML, and GDT EMR Connectivity

What’s in the Box

  • EasyOne Pro Portable DLCO, Lung Volumes, & Spirometry Testing System
  • DLCO Valve
  • Flow Sensor
  • Patient Gas Supply Tube
  • One-Way Valve
  • Gas Hose
  • Temperature/Humidity Sensor
  • DLCO Regulator (E or H/K)
  • User Manual
  • 2-Year Manufacturer's Warranty

WARRANTY: 2 Years or 3 Years

RETURNS: ITEMS WITH A LEAD TIME LONGER THAN 48 HOURS CANNOT BE RETURNED / CANCELLED. These are specially ordered, and we cannot accept returns or cancellations on such products for any reason. We take the responsibility to make sure your product arrives in brand new working condition. Should your item arrive damaged, we will replace the product at no cost to you.

Items which ship out in 24-48 hours are covered by our standard 30 day return policy from date of shipment. Return shipping charges are the responsibility of the customer. The product must be in new condition and in its original packaging.

For complete details of our return policy and process, please refer to our general return policy page.

Test
Test Type
Forced Vital Capacity (FVC/FVL), Slow Vital Capacity (SVC), Maximum Voluntary Ventilation (MVV), Bronchial Provocation, Quick Test, CO Diffusing Capacity (DLCO); Pro LAB adds FRC (Functional Residual Capacity) test
Report Type
Not specified
Volume Range
±12 l (measuring range, volume)
Flow Range
±16 l/s (measuring range, flow)
Accuracy
Volume: ±2% or 0.050 l · Flow: ±2% or 0.020 l/s (except PEF) · PEF: ±5% or 0.200 l · MVV: ±5% or 5 l/min
Reproducibility
Not specified
Power
Power Supply Type
Mains-powered, 100–240V, 50–60Hz, 80VA max
Sensor
Sensor Type
Ultrasonic transit-time flow sensor (hand-held, with removable DLCO valve unit); also includes NDIR CO sensor, ultrasonic molar mass sensor, and temperature/humidity sensor
Interpretation
Details
Automatic interpretation available using GOLD-Hardie or NLHEP criteria (selectable/deselectable in configuration)
Parameters
Details
Not specified
Predictive Norms
Details
Spirometry: NHANES III, Knudson 83/76, Crapo, Morris, Hsu, Dockery (Harvard), Polgar, Gutierrez (Canada), Eigen, Pereira, Pérez-Padilla (PLATINO/Mexico), Chile 2010/1997, ERS (ECCS/EGKS), Zapletal, Stanojevic/Quanjer 2012 (GLI), Rosenthal, Austria, Sapaldia (Swiss), Roca (SEPAR), and others. Lung capacity/DLCO: Ayers, Burrows, Crapo, Goldman & Becklake, Knudson, McGrath & Thompson, Miller, Gutierrez, Klement, NHANES, Polgar, ERS, Zapletal, Roca, Hedenström, Gulsvik, Pereira 2008, Thompson
Connectivity
Details
USB and LAN ports; GDT interface for EMR/EHR data export; network drive mapping supported; USB flash drive supported for backup/export and software updates
Compatibility
EHR Compatibility
Integrates via GDT interface (German GDT standard example given); EMR system selectable in software settings (example cited: TurboMed)
Operating System Requirements
Built-in industrial PC running Windows XP Embedded
Certifications
Standards
CE Declaration of Conformity; Protection Class I; Type BF applied part
Warranty
Main Device
Not specified
Accessories
Not specified
  • Compare products

    {"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

    Select first item to compare

    Select second item to compare

    Select third item to compare

    Compare