  • 80 Samples per Hour with Results in 60 Seconds
  • 100-Tube Autoloader with Continuous Random Access
  • CBC + 5-Part Differential Across 20 Parameters
  • Integrated Color Touch Screen Validation Station
  • STAT Mode for Urgent Samples on Open or Closed Tubes
  • Customized Dilution Ratio (CDR) Eliminates Manual Dilutions .

The Horiba ABX Pentra XL 80 is a high-throughput hematology analyzer that processes up to 80 samples per hour with a 100-tube autoloader, full CBC + 5-part WBC differential, and an integrated onboard validation station. It's built for hospital core labs and reference centers that need fast, accurate results without constant staff intervention.

✔ 80 Samples/Hour | ✔ 100-Tube Autoloader | ✔ Integrated Validation Station


SPEED AND CAPACITY WITHOUT COMPROMISE

80 SAMPLES/HOUR: Processes a full CBC + 5-part differential in 60 seconds per sample, keeping pace with high-volume lab demand without sacrificing accuracy.

100-TUBE AUTOLOADER: Continuous random-access loading means tubes can be added or removed mid-run without stopping the analyzer or interrupting the queue.

STAT MODE: Urgent samples can be inserted at any point for immediate processing on both open and closed tubes, no need to pause the current run.

AUTOMATIC SAMPLE RE-RUN: Out-of-range results are automatically flagged, re-sampled, and diluted using the Customized Dilution Ratio (CDR), eliminating the need for manual repeat testing.


ACCURATE RESULTS

INTEGRATED VALIDATION STATION: The 12" color LCD touch screen displays all 20 parameters, histograms, color matrix, flags, and comments on a single screen for fast result review without a separate workstation.

MDSS + DHSS TECHNOLOGY: HORIBA's patented micro-sampling and double hydrodynamic sequential system ensures precise mixing and accurate WBC differentiation — including neutrophils, lymphocytes, monocytes, eosinophils, and basophils.

VIRTUAL RACK MAPPING: On-screen display shows tube position, rack number, and test type (CBC or CBC + DIFF) for complete sample traceability throughout the run.

LIS CONNECTIVITY: Transmits patient and QC results to your lab information system via ASTM protocol with uni- or bidirectional connection, fully integrated into your existing workflow.


The Horiba ABX Pentra XL 80 is a high-volume hematology workhorse that keeps your lab moving with accurate results, minimal reruns, and full process visibility from loading to validation.

Warning WARNING: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.

  • 80 Samples per Hour with Results in 60 Seconds
  • 100-Tube Autoloader with Continuous Random Access
  • CBC + 5-Part Differential Across 20 Parameters
  • Integrated Color Touch Screen Validation Station
  • STAT Mode for Urgent Samples on Open or Closed Tubes
  • Customized Dilution Ratio (CDR) Eliminates Manual Dilutions

What’s in the Box

  • Horiba Pentra XL 80 Hematology Analyzer
  • Warranty
  • User Manual

RETURNS: Tiger Medical offers a 30-day return policy from date of shipment for this product, subject to a 20% restocking fee, in addition to the return shipping charges. The product must be in brand new condition and in its original packaging. We take the responsibility to make sure this product arrives in brand new working condition. Should your item arrive damaged, we will take full responsibility and replace the product at no cost to you. For complete details of our return policy and process, please refer to our general return policy page.

Cancellations: Items made to order, cannot be returned or canceled after production.

Dimensions
Depth
22.4 in / 57 cm
Height
21.5 in / 54 cm
Weight
122 lbs / 55 kg
Width
32.3 in / 82 cm
Base Properties
Throughput
Up to 80 samples/hour (open or closed tube)
Sample Volume
35 µL (CBC mode); 53 µL (CBC + DIFF mode)
Data Storage
10,000 results + graphics
Quality Control
24 selectable QC files; XB: 60 operator-selectable files with statistics (20 results per file); Within run; Levey-Jennings graphs
Sample No
100 tubes (10 racks x 10 tubes); continuous random access
Peripheral Output Options
Laser printer; RS 232C; 2x USB1; uni- and bi-directional LIS connection; ASTM protocol; CD-ROM drive; floppy disk
Processing system
12 in. color LCD touch screen; Windows XP Pro; Celeron 566 MHz onboard PC; RAM 256 MB; Hard disk 10 GB min.
Dryer
N/A
Temperature (refrigerated chamber)
N/A
Cleaning agent
ABX Cleaner (onboard reagent)
Waste disposal
N/A
Slide collection drawer
N/A
Parameters
CBC Results
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW CV, RDW SD, PLT, MPV
Differential Results (absolute and %)
NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, ALY# & ALY%, LIC# & LIC%
Reticulocyte Results (absolute and %)
N/A
Manufacturer's reagents
Diluent, Lysebio (cyanide-free lyse), Cleaner, Eosinox, Basolyse II
Body Fluids (Spinal, Serous and Synovial)
N/A
Power
Power Consumption
Maximum 230 VA; maximum heat output 670 kJ/h (635 BTU/h)
Power requirements
100 V to 240 V (±10%), 50–60 Hz
Whole Blood Performance - Measuring Range
WBC
0 – 120 x 10³/µL (Standard) 120 – 360 x 10³/µL (with CDR)
RBC
0 – 8 x 10⁶/µL (Standard) 0 – 8 x 10⁶/µL (with CDR)
HGB
0 – 24 g/dL (Standard) 0 – 24 g/dL (with CDR)
MCV
N/A
PLT
Whole Blood: 0 – 2,800 x 10³/µL (Standard) 2,800 – 5,600 x 10³/µL (with CDR) Concentrate: 0 – 2,800 x 10³/µL (Standard) 2,800 – 5,600 x 10³/µL (with CDR)
Sample Transport Capabilities
Capacity
100 tubes (10 racks of 10); sample mixing via end-over-end tube rotation; closed or open STAT tube access
Stain
Stained slide dryer
N/A
Carrier, continuous load
N/A
Slides/hr
N/A
Cellular applications
N/A
Other attributes
N/A